设备技术
压力测量check_box_outline_blank是的check_box_outline_blank不 燃气检测check_box_outline_blank是的check_box_outline_blank不 个人防护check_box_outline_blank是的check_box_outline_blank不 漏水检测check_box_outline_blank是的check_box_outline_blank不 线路和瓶盖定位check_box_outline_blank是的check_box_outline_blank不 LTE模块check_box_outline_blank是的check_box_outline_blank不 蓝牙check_box_outline_blank是的check_box_outline_blank不 爆炸保护check_box_outline_blank是的check_box_outline_blank不 H2准备100%check_box_outline_blank是的check_box_outline_blank不 H2准备高达30%check_box_outline_blank是的check_box_outline_blank不 红外线check_box_outline_blank是的check_box_outline_blank不 Portable gas leak detector with integrated pump, bluetooth and Li-Ion battery for leak detection using forming gas (5% H2 in 95% N2).
Extremely resistant 2K plastic housing
Operating time > 35 hours (depending on ambient conditions, without lighting)
Pump flow approx. 20 l/h
Dimensions (LxWxH): 170 x 80 x 43 mm,
Weight: approx. 380 gGas detection device for easily locating even the
smallest leaks in pipes using forming gas (5 Vol.% H2 in N2)
- highly sensitive hydrogen sensor with a resolution of 0,1 ppm H2
- extremely fast reaction to the smallest traces of hydrogen
- second sensor for pinpointing in probe holes
- integrated pump with high power for flow and for negative pressure
Operation time:
> 10 hours without lighting
Measuring ranges:
0 to 1000 ppm H2
0 to 5 Vol.% H2 in N2
dimensions: approx. 200 x 100 x 87 mm
weight: approx. 1100 gGasTest delta3 Measurement instrument for indoor gas installation
Pressure and leak measurement instrument in accordance
with DVGW G 600, G 5952.
Operating time varies depending on the way of usage and power consumption
(e.g. serviceability in accordance with G 5952 approx. 50 tests)
Serviceability test (measurement range 0 - 10 l/h)
Gastightness test (measurement range 0 - 300 hPa)
Load test (measurement range 0 - 1000 hPa)
Serviceability test in accordance with G 5952 and with Esders express procedure
Automatic and manual test on regulators (optional)
Test on service lines in accordance with DVGW G 459-1
using G 469 B3 procedure (optional)
- Automatic regulator test including storage of outlet pressure
(flowing gas and standing gas), SSV overpressure cut-off and gastight closure
- Manual regulator test including storage of outlet pressure
(flowing gas and standing gas), SRV threshold pressure and gastight closure,
SSV overpressure and underpressure cut-off and gastight closure
- Gas detection via external, digital handheld sensor possible
- Pressure test up to 25 bar via external sensors possible
- Data storage, infrared and bluetooth interface
- Display with touch function to enter address data, project number,
meter and/or regulator number, etc.
Dimensions: 192 x 100 x 87 mm
Weight: approx. 1160 g
Electronic pressure test case for pressure tests
with connection possibility of up to 5 external pressure or temperature sensors.
- the test procedures are menu-guided and can be carried out with
simple Data entry dialog
- a freely programmable pressure test is included
- optional test sequences for gas and water tightness tests
e.g. according to DVGW, ÖVGW, EWE, Avacon, WEVG.
- a subsequent addition of test sequences is possible easily
- large, illuminated display, even in direct sunlight easy to read
- data entry and signature via touch display and foil keys
- stylus for the touch display included
- data memory for hundreds of measurements, depending on
test sequence
- communication via Bluetooth for updates and data transmission
(costs may apply for data transmission to the cloud)
- LTE / GPS module (optional)
- robust case (IP 67)
- operating time approx. 200 hours, extension with power supply
possible from outside
Dimensions: 220 x 90 x 168 mm
Weight: approx. 1450 gGas measurement & warning device with certified measuring function for explosion protection.
This variant of the OLLI is included in the BG RCI list of function-tested gas detectors (see article 280000 for the variant without certification).
Explosion-proof & compact diffusion hand-held measuring device.
It can be used for up to 5 combustible and toxic gases as well as oxygen and comes in an extremely rugged 2C synthetic housing with rechargeable and explosion-proof Li-ion battery pack.
Charging the battery in potentially explosive atmospheres is not permitted!
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based on customer requirements. The device can optionally be equipped with a pump and pressure sensor.
Operating time > 50 hours (depending on type & number of installed sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument (active & passive)
Measuring function certified for methane (CH4), propane (C3H8), oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2), hydrogen sulfide (H2S) according to the following standards:
EN 60079-29-1
EN 50104
EN 45544-1
EN 45544-3
ATEX Marking: II 2G Ex ib db IIB T4 Gb
(EU-)type examination certificates:
BVS 17 ATEX E 043 X
TÜV 21 ATEX 8596 X
TÜV 21 PTG 7001 X
968/FSP 1940.05/21
Kennzeichnung IECEx:
Ex ib db IIB T4 Gb
IECEx BVS 21.0085X
Temperature range: -20°C <= Ta <= +50°CHighly sensitive and selective gas detection & gas measurement device with
laser technology for the inspection of underground gas pipes using suitable
probes (e. g. carpet probe). The device can also be used for the vehicle-based
pipeline inspection.
With built-in diaphragm pump, Bluetooth module and rechargeable
Li-Ion battery.
One out of two different laser modules can be assembled:
- single laser module for methane or
- dual laser module for methane & ethane
Moreover, the device can be equipped with additional sensors
to enable further applications.
The following applications are possible:
- Inspection of underground pipes
- Inspection of accessible pipes in buildings
- Inspection of accessible pipes on plants, etc.
- Inspection of ground soil for pinpointing (optional)
- Purging of gas pipelines (optional, only in combination with pinpointing)
- Gas analysis (with dual laser module)
Operating time up to 10 hours
Measurement range depending on built-in sensors
Dimensions (LxWxH): 143 x 240 x 85 mm
Weight: 2.1 kg
Temperature ranges:
0 °C to 40 °C (dual laser module)
-10 °C to 50 °C (single laser module)Gas detection device for easily locating even the
smallest leaks in water and heating systems
- special, highly sensitive hydrogen sensor with a resolution of 0,1 ppm H2
- extremely fast reaction to the smallest traces of hydrogen
- second sensor for pinpoint localisation in probe holes
- integrated pump with high power for flow and for negative pressure
Operation time:
> 10 hours without lighting
Measuring ranges:
0 to 1000 ppm H2
0 to 5 Vol.% H2 in N2
dimensions: 200 x 100 x 87 mm
weight: approx. 1100 g
temperature range: -10°C to +50°C
Gas detection & gas measurement device for the inspection
of underground gas pipes using suitable probes (e. g. carpet probe).
With built-in diaphragm pump, Bluetooth module and rechargeable
Li-Ion battery.
The device can be equipped with additional sensors to enable
further applications.
The following applications are possible:
- Inspection of underground pipes
- Inspection of accessible pipes in buildings
- Inspection of accessible pipes on plants, etc.
- Inspection of ground soil for pinpointing (optional)
- Purging of gas pipes (optional, only in combination with pinpointing)
Operating approx. 10 hours
Measurement ranges depending on built-in sensors
Dimensions (LxWxH): 100 x 195 x 86 mm
Weight: 1.1 kg
Temperature range: -10°C to 50°CGOLIATH RN with Ethane analysis methane and toxic gases
Detect - Measure - Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing - Above ground inspection
- Building inspection - Bar hole testing
- Purging gas purity - Ethane analysis
Measurement ranges:
- methane ppm, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°CDruktest max test case for tightness measurements with internal pressure sensor
with an accuracy of 0.25 %, resolution up to 0.1 mbar, measuring range up to 1.6 bar.
- menu-guided test procedures:
- G-07 and G-12 included
- G-22 to MOP 100 mbar (optional)
- Pressure test free (optional)
- large, illuminated display, easy to read even in direct sunlight
- data input and signature via touch display
- internal pump and pressure release valve for automatic test pressure generation
- data memory for hundreds of measurements, depending on test procedure
- communication via Bluetooth
- LTE / GPS module (optional)
- robust case (IP 67)
- operating time several days, depending on test procedure
- dimensions: approx. 263 x 205 x 110 mm, weight: approx. 2300 g
Gas measurement & warning device without certified measuring function for explosion protection.
This variant of the OLLI is NOT on the BG RCI list of function-tested gas detectors (see article 280010).
Explosion-proof & compact handheld gas measurement instrument
as diffusion device.
It can be used for up to 5 combustible and toxic gases as well as oxygen and comes in an extremely rugged 2C synthetic housing with 3 alkaline manganese primary cells.
Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based on customer requirements. The device can be optionally equipped with a Li-ion battery pack, pump and pressure sensor.
Operating time > 50 hours (depending on type & number of installed sensors and ambient conditions, w/o illumination)
Measurement ranges are subject to sensor assembly
Dimensions: 136 x 78 x 43 mm
Weight: approx. 350 g
Explosion-proof measurement instrument,
ATEX marking:
II 2G Ex ib db IIB T4 Gb
BVS 17 ATEX E 043 X
Marking (IECEx):
Ex ib db IIB T4 Gb
IECEx BVS 21.0085X
Temperature range: -20°C <= Ta <= +50°CELLI Esders Laser Leak Indicator Set
ELLI is an innovative, portable laser methane (CH4)
measuring instrument that can be easily monitor
difficult or impossible to reach areas and hazardous
areas from a distance.
Technical data:
Calibration gas: methane (CH4)
Display: color LCD touch screen
Scanning range: 30 m standard, 50 m under good reflection conditions
Reaction time: 0.1 seconds
Detection method: tuneable diode laser absorption spectroscopy (TDLAS)
Weight: approx. 1,6 kg
Dimensions: approx. 237 x 167 x 74 mm
Measuring range: 0 ... 50.000 ppm x m
Temperature range: -17°C to 50°C
Humidity: 5 to 90% rel. humidity
Protection class: IP54
Operating time: 8 hours per charge (6 hours charging time)
Power supply: rechargeable Li-ion battery
Connections: USB, earphone, GPS, bluetooth
Scope of delivery: earphones, carrying belt, rugged carrying case,
chargermethane/propane and toxic gases
Detect - Warn - Measure
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Confined space entry
- Building inspection
- Bar hole testing
- Purging gas purity
Measurement ranges:
- methane ppm, LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- propane ppm, LEL, Vol.% (optional)
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- pressure measurement 0 - 2.000 hPa (optional)
- flow speed measurement (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°CKit includes:
- EyeCGas Multi Camera
- Multi Spectral Filters (VOC und CO2)
- 2x EyeCGas Battery
- EyeCGas Singel Battery Charger
- EyeCGas Multi Carrying Case
- EyeCGas Glare Shield
- EyeCGas Shoulder Strap
- EyeCGas Lens Pen Cleaner
Rugged, explosion proofed gas measurement instrument
with internal membrane pump and reachargeable
NiMH-battery
for the specific use in biogas, landfill and sewage gas.
Operating time > 8 to > 12 hours depending on application
(without backlight)
Measurement ranges:
- methane 0 - 100 Vol.% CH4
- carbon dioxide 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- hydrogen sulphide 0 - 1000 ppm H2S (optional)
- hydrogen sulphide 0 - 2000 ppm H2S (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1200 g
Explosion proofed instrument:
Sign: ll 2G Ex ib d llB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C < Ta < +40°Cmethane and toxic gases
Detect - Warn - Measure - Analyse
Rugged, explosion proofed measurement instrument
with internal membranpump and reachargeable
NiMH-
battery.
Operating time: depending on application and backlight
Application in accordance with DVGW G 465-4:
- Enclosed space testing
- Above ground inspection
- Confined space entry
- Building inspection
- Bar hole testing
- Purging gas purity
- Ethane analysis
Measurement ranges:
- methane ppm, LEL, Vol.%
- carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2
- oxygen 0 - 25 Vol.% O2 (optional)
- carbon monoxide 0 - 500 ppm CO (optional)
- hydrogen sulphide 0 - 100 ppm H2S (optional)
- pressure measurement 0 - 2.000 hPa (optional)
Dimensions: 200 x 100 x 87 mm
Weight: approx. 1250 g
Explosion proofed instrument:
Sign: II 2G Ex ib d IIB T3/T4 Gb
BVS 09 ATEX E 079 X
Temperature range: -10°C <= Ta <= +40°CThermal printer with infrared and bluetooth interface.
- paper width: 58 mm
- powered by rechargeable battery
The power supply 230 V (item number: 202002) can be used
for charging the thermal printer.Pressure measuring device for water pipeline networks.
Measuring range up to 25 bar.
Accuracy better than 0,1% from final value.
Pressure side with DIN underground hydrant screw connection and ¼ internal thread.
Cap with magnet for operating the logger.
Robust and reliable CO detector with a limited operating time after activation of up to 2 years.
The single gas can be checked daily (bump test) and
be calibrated and adjusted by means of test gas and the corresponding infrared
communication module integrated event memory.
The IR interface allows changes of the alar thresholds and reading of the event memory
by means of the IR communication module and PC software
ATEX II 1G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4VibraGAS EX HMG2 - rechargeable battery
Gas leak detector
Small, rugged aluminium handheld gas leak detector with
remote sensor on the swan neck and lighted display.
Display of gas traces by audible, visual and vibrating alarm.
measurement ranges: 0 to 10.000 ppm methane
operating time: > 12 hours without backlight and 20°C
dimensions: 149 x 58 x 34 mm (plus 172 mm goose neck)
weight: approx. 450 g
explosion-proof instrument:
sign: II 2G Ex ib d IIB T3 Gb
BVS 05 ATEX E 010 X
temperature range: -20°C < Ta < +50°C