产品
文章隶属关系:
Option AGFW FW 602
Menu-guided pressure test procedures for carrying out pressure tests on district heating pipes
according to AGFW FW 602 (Germany):
- Differential pressure measurement method (air)
- Pressure measurement method (air)
- Simultaneous pressure measurement (air)
- Water pressure test
Option EN 805
Menu-driven test procedures for pressure tests on water pipes according to rules and regulations of EN 805 (Europe):
- Contraction procedure
- Normal procedure
smart memo
Electronic pressure test case for pressure tests
with connection possibility of up to 5 external pressure or temperature sensors.
- the test procedures are menu-guided and can be carried out with
simple Data entry dialog
- a freely programmable pressure test is included
- optional test sequences for gas and water tightness tests
e.g. according to DVGW, ÖVGW, EWE, Avacon, WEVG.
- a subsequent addition of test sequences is possible easily
- large, illuminated display, even in direct sunlight easy to read
- Data entry and signature via touch display and foil keys
- Stylus for the touch display included
- Data memory for hundreds of measurements, depending on
test sequence
- Communication via Bluetooth for update, data transmission, printer
- LTE / GPS module (optional)
- robust case (IP 67)
- Operating time approx. 200 hours, extension with power supply
possible from outside
Dimensions: 220 x 90 x 168 mm
Weight: approx. 1450 g
Description
The stainless steel test body "Heinz" is used e.g. for pressure tests on gas and water pipes and offers four practical connections made of nickel-plated brass or stainless steel. They are used to connect the pressure sensor, to let in and drain water or gas and to connect the control manometer. When draining water, the DWZ2 - our digital water meter, can be connected with quick coupling. The test piece has an external thread of 2 ½" and is suitable for pressure tests up to 60 bar. All quick couplings are equipped with protective caps for safety and are thus protected against dirt or water. With the optional test adapters, a tight transition to many threads and fittings is achieved.